Polymer-Based Columns (RSpak)

Partition and adsorption chromatography is the most widely used analytical method in HPLC analysis. Shodex polymer-based columns for partition and adsorption chromatography (reversed and normal phase) is superior to silica-based media in range of eluent selection, lot reproducibility and durability. In addition to standard columns with ID 4.6-8.0mm, we provide micro columns with ID 300micron-800micron, semi-micro columns with ID 1.0mm-2.0mm and preparative columns with ID 10mm and above.

RP18-415 Suitable for protein and peptide analysis because of the large pore size (450 angstrom)
RP18-613,413 High performance version (high theoretical plate number) of DS-613 and DS-413.
DS-613,413 Because they are packed with low polarity polymers (styrene divinyl benzene), these are suitable for analysis by reversed phase of highly hydrophilic substances which cannot be well-retained by ODS columns.
DE Series These columns have the widest application among the RSpak. Since they are packed with polymer-based material that have almost equal polarity as silica-based material bonded with C-18 groups, chromatography similar to ODS columns can be obtained. They have a wide application and can be used with eluent conditions that are not compatible with standard ODS columns, such as "can be used in analysis with 100% water" and "can be used in analysis and cleaning with alkali eluent". Separation characteristics of the DE series are slightly different from those of the Asahipak ODP series because of the difference in packing material.
DM-614 Suitable for analysis of amino acids and polypeptides.
DC-613 Suitable for analysis of saccharides in normal phase.
NN-814,614,414 Multimode column with reversed phases and cation exchange.
These columns incorporate a trace amount of sulfo group in the packing material of the reversed phase columns. Separation of neutral substances is by reversed phase mode, of basic substances by reversed phase and ion exchange mode and of acidic substances by ion exclusion and reversed phase mode. They are therefore suitable for analysis of complex samples that have a mixture of neutral substances and ionic substances.
JJ-50
(old name) SS-50

Multimode column with reversed phases and anion exchange.
These columns incorporate a trace amount of quaternary ammonia group in the packing material of the reversed phase columns. Separation of neutral substances is by reversed phase mode, of basic substances by ion exclusion and reversed phase mode and of acidic substances by reversed phase and ion exchange mode. They are therefore suitable for analysis of complex samples that have a mixture of neutral substances and ionic substances.


RSpak RP18-415, 613, 413

(Standard columns)
Product name Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
RSpak RP18-415
RSpak RP18-613
RSpak RP18-413
RSpak RP18-G
> 5,000
> 13,000
> 11,000
Guard column
6
3.5
3.5
6
4.6 x 150
6.0 x 150
4.6 x 150
4.6 x 10
Product name Max. usable
pressure
(MPa)
Max. usable
flow rate
(mL/min)
Usable
temp. range
(deg-C)
Usable
pH range
Usable salt
conc.
In-column
solvent
RP18-415
RP18-613
RP18-413
RP18-G
22
22
22
-
1.5
1.5
1.0
-
RT to 50
RT to 50
RT to 50
RT to 50
1 to 13
1 to 13
1 to 13
1 to 13
< 0.5M
< 0.5M
< 0.5M
< 0.5M
CH3CN/H2O=80/20
CH3CN/THF/H2O=30/30/40
CH3CN/THF/H2O=30/30/40
CH3CN/THF/H2O=30/30/40
When you do not use a column, please keep it between pH 2 to 12.
In the case of keeping a column for a long time, please replace with the shipping solvent in the column.

Eluent conditions:
Product name Toluene
Chloroform etc.
Methanol Acetonitrile THF Water solusiton
RP18-415
RP18-613
RP18-413

0 to 50%
0 to 50%
0 to 50%

0 to 100%
30 to 100%
30 to 100%

0 to 100%
10 to 100%
10 to 100%

0 to 50%
5 to 100%
5 to 100%

0 to 100%
cannot use 100% Water solusiton
cannot use 100% Water solusiton


RSpak DS-613, 413, 2013, 5013
(Standard columns)
Product name Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
RSpak DS-613
RSpak DS-413
RSpak DS-G
> 6,500
> 11,000
Guard column
6
3.5
10
6.0 x 150
4.6 x 150
4.6 x 10
Product name Max. usable
pressure
(MPa)
Max. usable
flow rate
(mL/min)
Usable
temp. range
(deg-C)
Usable
pH range
>Usable
salt conc.
In-column
solvent
DS-613
DS-413
DS-G
10
20
-
3.0
1.0
-
RT to 80
20 to 50
RT to 80
2 to 12
*1 to 13
*1 to 13
< 0.5M
< 0.5M
< 0.5M
CH3CN/THF/H2O=40/30/30
CH3CN/THF/H2O=30/30/40
-
When you do not use a column, please keep it between pH 2 to 12.
In the case of keeping a column for a long time, please replace with the shipping solvent in the column.
Eluent conditions: Please refer to Eluent conditions for RSpak D sereies.

RSpak DE Series
(Standard columns)
Product name Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
Applications
RSpak DE-613
RSpak DE-413
RSpak DE-413L
RSpak DE-413S
RSpak DE-G
RSpak DE-213
RSpak DE-SG
> 7,000
> 11,000
> 17,000
> 3,000
Guard column
> 8,000
Guard column
6
4
4
4
10
4
4
6.0 x 150
4.6 x 150
4.6 x 250
4.6 x 50
4.6 x 10
2.0 x 150
2.0 x 10



Column-switching

LC/MS analyses
Product name Max. usable
pressure
(MPa)
Max. usable
flow rate
(mL/min)
Usable
temp. range
(deg-C)
Usable
pH range
>Usable
salt conc.
In-column
solvent
DE-613
DE-413
DE-413L
DE-413S
DE-G
DE-213
DE-SG
7
15
18
-
-
12
-
3.0
1.2
1.2
-
-
0.4
-
RT to 70
RT to 60
RT to 60
RT to 60
RT to 70
RT to 60
RT to 60
2 to 12
2 to 12
2 to 12
2 to 12
2 to 12
2 to 11
2 to 11
< 0.5M
< 0.5M
< 0.5M
< 0.5M
< 0.5M
< 0.5M
< 0.5M
H2O
CH3CN/H2O=50/50
CH3CN/H2O=50/50
CH3CN/H2O=50/50
H2O
CH3CN/H2O=50/50
-
Eluent conditions: Please refer to Eluent conditions for RSpak D sereies.

(Micro column and Semi-micro columns)(Remark)
Product name Size(mm)
ID x Length
Standard
column
DE413-2E
DE413-2D
DE413-2B
DE413-2T
2.0 x 250
2.0 x 150
2.0 x 50
2.0 x 35
DE-413
DE413-1E
DE413-1D
DE413-1B
DE413-1T
1.0 x 250
1.0 x 150
1.0 x 50
1.0 x 35
DE-413
DE413-M8D
DE413-M8B
DE413-M8T
0.8 x 150
0.8 x 50
0.8 x 35
DE-413
DE413-M5D
DE413-M5B
DE413-M5T
0.5 x 150
0.5 x 50
0.5 x 35
DE-413
DE413-M3D
DE413-M3B
DE413-M3T
0.3 x 150
0.3 x 50
0.3 x 35
DE-413

(Preparative Columns)(Remark)
Product name Particle size
(micron)
Size(mm)
ID x Length
Standard
column
RSpak DE-2013
RSpak DE-LG
12
12
20.0 x 300
8.0 x 50
DE-613
Guard column
RSpak DE-5013
RSpak DE-LLG
12
12
50.0 x 500
20.0 x 100
DE-613
Guard column


RSpak DM-614, 2013, 5013
(Standard columns)
Product name Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
RSpak DM-614
RSpak DM-G
> 4,500
Guard column
10
12
6.0 x 150
4.6 x 10
Product name Max. usable
pressure
(MPa)
Max. usable
flow rate
(mL/min)
Usable
temp. range
(deg-C)
Usable
pH range
Usable
salt conc.
In-column
solvent
DM-614
DM-G
2
-
2.0
-
RT to 60
-
2 to 10
-
< 0.5M
-
0.005M H3PO4
-
Eluent conditions: Please refer to Eluent conditions for RSpak D sereies.

(Preparative Columns)(Remark)
Product name Particle size
(micron)
Size(mm)
ID x Length
Standard
column
RSpak DM-2014
RSpak DM-LG
12
12
20.0 x 300
8.0 x 50
DM-614
Guard column
RSpak DM-5014
RSpak DM-LLG
12
12
50.0 x 500
20.0 x 100
DM-614
Guard column

RSpak DC-613, 2013, 5013
(Standard columns)
Product name Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
RSpak DC-613
RSpak DC-G
> 5,500
Guard column
6
10
6.0 x 150
4.6 x 10
Product
name
Max. usable
pressure
(MPa)
Max. usable
flow rate
(mL/min)
>Usable
temp. range
(deg-C)
Usable
pH range
Usable
salt conc.
In-column
solvent
DC-613
DC-G
5
-
3.0
-
40 to 85
40 to 85
2 to 14
2 to 14
< 0.5M
< 0.5M
CH3CN/H2O=70/30
CH3CN/H2O=70/30
Eluent conditions: Please refer to Eluent conditions for RSpak D sereies.

(Preparative Columns)(Remark)
Product name Particle size
(micron)
Size(mm)
ID x Length
Standard
column
RSpak DC-2013
RSpak DC-LG
10
10
20.0 x 300
8.0 x 50
DC-613
Guard column
RSpak DC-5013
RSpak DC-LLG
10
10
50.0 x 500
20.0 x 100
DC-613
Guard column


RSpak NN Series

(Standard columns)
Product name Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
RSpak NN-814
RSpak NN-G
RSpak NN-614
RSpak NN-414
> 9,000
Guard column
> 4,000
> 6,000
10
10
10
10
8.0 x 250
6.0 x 50
6.0 x 150
4.6 x 150
Product name Max. usable
pressure
(MPa)
Max. usable
flow rate
(mL/min)
Usable
temp. range
(deg-C)
Usable
pH range
Usable
salt conc.
In-column
solvent
NN-814
NN-G
NN-614
NN-414
2.0
-
1.5
1.2
1.5
-
1.0
0.5
10 to 50
10 to 50
10 to 50
10 to 50
2 to 12
2 to 12
2 to 12
2 to 12
< 0.5M
< 0.5M
< 0.5M
< 0.5M
0.1M NaH2PO4
0.1M NaH2PO4
0.1M NaH2PO4
0.1M NaH2PO4
Eluent conditions: Please refer to Eluent conditions for RSpak NN sereies.

(Micro column and Semi-micro columns)(Remark)
Product name Size(mm)
ID x Length
Standard
column
NN414-2D
NN414-2B
NN414-2T
2.0 x 150
2.0 x 50
2.0 x 35
NN-414
NN414-1D
NN414-1B
NN414-1T
1.0 x 150
1.0 x 50
1.0 x 35
NN-414
NN414-M8D
NN414-M8B
NN414-M8T
0.8 x 150
0.8 x 50
0.8 x 35
NN-414
NN414-M5D
NN414-M5B
NN414-M5T
0.5 x 150
0.5 x 50
0.5 x 35
NN-414
NN414-M3D
NN414-M3B
NN414-M3T
0.3 x 150
0.3 x 50
0.3 x 35
NN-414

RSpak JJ-50
(Standard columns)
Product name Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
RSpak JJ-50 4D
RSpak JJ-50 2D
> 4,500
> 3,500
5
5
4.6 x 150
2.0 x 150
Product name Max. usable
pressure
(MPa)
Max. usable
flow rate
(mL/min)
Usable
temp. range
(deg-C)
Usable
pH range
Usable
salt conc.
In-column
solvent
JJ-50 4D
JJ-50 2D
9.0
9.0
1.2
0.3
10 to 60
10 to 60
2 to 10
2 to 10
< 0.1M
< 0.1M
0.005M H3PO4
0.005M H3PO4

Products | Precautions for use | Technical info | Troubleshooting