Standard Type GPC Column

(In-column solvents)
THF(Tetrahydrofuran) These most common GPC columns use versatile THF as in-column solvent.
Chloroform These columns use chloroform, the second most common solvent, as in-column solvent.
DMF(Dimethylformamide) These columns use DMF as in-column solvent, which is suitable for analysis of polar polymers, such as melamine resin, polyacrylonitrile, polyvinylpyrrolidone, polyimide resin. GFC columns of the OHpak SB-800 HQ series are also fit for use of DMF.

(Standard Columns)
In-column solvent Exclusion limit
(Polystyrene)
Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
KF(THF)
GPC KF-801
GPC KF-802
GPC KF-802.5
GPC KF-803
GPC KF-803L
GPC KF-804
GPC KF-804L
GPC KF-805
GPC KF-805L
GPC KF-806
GPC KF-806M
GPC KF-806L
GPC KF-807
GPC KF-807L
GPC KF-G
1,500
5,000
20,000
70,000
70,000
400,000
400,000
4,000,000
4,000,000
(20,000,000)
(20,000,000)
(20,000,000)
(200,000,000)
(200,000,000)
Guard column
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 11,000
> 11,000
> 11,000
> 13,000
> 11,000
> 6,000
> 6,000
-
6
6
6
6
6
7
7
10
10
10
10
10
18
18
8
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
4.6 x 10
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 2.0mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60deg-C

In-column solvent Exclusion limit
(Polystyrene)
Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
K(Chloroform)
GPC K-801
GPC K-802
GPC K-802.5
GPC K-803
GPC K-803L
GPC K-804
GPC K-804L
GPC K-805
GPC K-805L
GPC K-806
GPC K-806M
GPC K-806L
GPC K-807
GPC K-807L
GPC K-G
1,500
5,000
20,000
70,000
70,000
400,000
400,000
4,000,000
4,000,000
(20,000,000)
(20,000,000)
(20,000,000)
(200,000,000)
(200,000,000)
Guard column
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 11,000
> 11,000
> 11,000
> 13,000
> 11,000
> 6,000
> 6,000
-
6
6
6
6
6
7
7
10
10
10
10
10
18
18
8
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
4.6 x 10
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 2.0mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60deg-C

In-column solvent Exclusion limit
(Polystyrene)
Plate number
(TPN/column)
Particle size
(micron)
Size(mm)
ID x Length
KD(DMF)
GPC KD-801
GPC KD-802
GPC KD-802.5
GPC KD-803
GPC KD-804
GPC KD-805
GPC KD-806
GPC KD-806M
GPC KD-807
GPC KD-G
2,500
5,000
20,000
70,000
400,000
4,000,000
(20,000,000)
(20,000,000)
(200,000,000)
Guard column
> 17,000
> 17,000
> 17,000
> 17,000
> 17,000
> 11,000
> 11,000
> 13,000
> 6,000
-
6
6
6
6
7
10
10
10
18
8
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
4.6 x 10
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 1.5mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60deg-C

Figures in parentheses are estimated valus.

Products | Precautions for use | Technical info | Troubleshooting