Eluent Degassing Device : DEGASSER ERC-3115alpha, 3215alpha, 3315alpha, 3415alpha

The new ERC-3000alpha series degasser for HPLC is a very compact high quality unit that comes with all of the safety features that chromatographers expect from the world's premiere manufacturer of eluent degassers. This newest, most advanced series of degassers removes the dissolved gas in HPLC eluents easily and efficiently.
Simply connect the unit in front of the pump to obtain stable chromatograms and reliable pump operation.

(Features)
* Small internal volume: solvent replacement is easy and quick. High performance: degassing performance is unsurpassed despite the small internal volume.
* Unique safety features: internal pressure and leak monitors work to prevent damage in unusual situations.
* Use with any HPLC pump; can even be used with quick-return type pumps due to low internal flow resistance.
* High quality: ERC degassers are designed, manufactured and tested in an ISO 9001 certified facility. All units also conform to CE safety specifications (EMC and LVD).
* Non-metallic solvent contact pans.



(Principle)
As the eluent flows through the degassing tube made of special macromolecular film, the dissolved gas will be removed through the tube wall when the ambient pressure is reduced. This pressure reduction is controlled by the built-in pressure sensor, controller and membrane vacuum pump.

(1) Membrane
(2) Vacuum chamber
(3) Pressure sensor
(4) Controller
(5) Three-way valve
(6) Vacuum pump
(7) Eluent
(8) HPLC pump



(Specifications)

ERC-3115alpha ERC-3215alpha ERC-3315alpha ERC-3415alpha
Solvent channels
1 channel
2 channels
3 channels
4 channels
Max. flow rate
20mL/min/channel (25deg-C deionized water)
Degassing capacity
Air bubble should not be observed at the outlet.
(Conditions)
Eluent: Deionized water
Flow rate: 3mL/min
Temperature: 25deg-C (Reference)
Oxygen concentration at the outlet was 2ppm under the above conditions.
Internal volume
7mL/channel
Solvent contactparts
PEEK (Inlet/Outlet port), PTFE (Membrane and tubing)
Displays

Functions
Power ON/OFF "POWER" LED turns on when power is on.
Status monitor "READY" LED turns on when the pressure is lower than
the designated value.
Pressure monitor "PRES." LED turns on when the pressure value is higher
than the designated value for the designated time.
Leakage monitor "LEAK" LED turns on when the leakage in the device is
detected.
Self cleaning Cleaning of vacuum tubing by incoming air.
Mode selection NORM: For ordinary use. CONT: For high performance
degassing.
Outputs
Open connector signal is output when "PRES." or "LEAK" LED turns on.
Dimensions
W71 x D310 x H136mm
Weight
ca 5.0kg
ca 5.1kg
ca 5.4kg
ca 5.5kg
Power source
AC 100 to 240 V, 50/60Hz (Free power source)
Power consumption
10VA

For applications requiring the use of strong acid such as sulfuric acid or HFIP (hexafluoroisopropanol), a specially designed type is available.
Besides the above types, 6 channel type and preparative types are available.
Contact your local distributor for additional information.